Skip to content
    Quality Assurance

    In-House Quality Control Laboratory

    30+ Parameters Tested on Every Batch

    B D Guar operates a dedicated in-house QC laboratory at our Kalol facility, staffed by qualified food scientists and chemists. Every batch of Guar Gum — food-grade, pharmaceutical-grade, or industrial — undergoes 30+ parameter testing before release. We do not rely on third-party labs for routine QC; results are available within 24 hours of batch completion.

    30+

    Parameters tested

    24h

    Result turnaround

    100%

    Batch testing

    ISO 17025

    Aligned methods

    Testing Categories

    Guar Gum is a functional ingredient, so a certificate that only reports moisture and ash tells a buyer very little about how the powder will behave in their process. Our panel is built around function as much as composition: viscosity development, hydration speed, particle size and microbiological safety are measured on every lot, because those are the variables that decide whether a validated formulation still performs on the next delivery.

    Rheological Testing

    • Brookfield viscometer (RVT / DV-II+) for food, pharma and cosmetic grades
    • Fann 35 viscometer for oil drilling grades
    • Viscosity measured at 1% and 2% concentration
    • Hydration rate (cP vs. time) curves for fast-hydrating grades
    • Temperature-dependent viscosity profiles

    Physical Analysis

    • Moisture content by IR moisture analyzer (< 12%)
    • Granulation and particle size distribution by Tyler mesh sieve analysis
    • Bulk density
    • Colour and appearance (visual plus colorimeter)
    • Foreign matter screening

    Chemical Analysis

    • pH of 1% solution
    • Ash content by muffle furnace (max 1.5%)
    • Acid-insoluble residue
    • Galactomannan content (minimum 80% for food grade)
    • Protein / nitrogen content by Kjeldahl

    Microbiological Testing

    • Total plate count (TPC)
    • Yeast and mould count
    • E. coli, Salmonella and Staphylococcus — absent
    • Coliforms
    • Tested per IS 7553 and USP/NF for pharmaceutical grades

    Residue & Contaminant Testing

    • Ethylene oxide (ETO) residue to the EU LOQ of 0.1 mg/kg
    • Heavy metals — lead, arsenic, cadmium, mercury — per EU limits
    • Pesticide residue screening (APEDA panel)
    • Aflatoxin B1 and total aflatoxins

    Application-Specific Testing

    • Drilling fluid performance to API 13A compliance
    • Hydration rate curves for fast-hydrating grades
    • Compatibility testing with specific food and cosmetic matrices
    • Stability studies (accelerated ageing at 40°C / 75% RH)

    Testing Equipment & Methods

    Instruments are calibrated on a documented schedule against traceable standards, and every analyst works to a written standard operating procedure for each method below. Where a parameter demands instrumentation beyond our in-house scope — trace ETO confirmation in particular — we route the sample to an NABL-accredited partner laboratory and attach their report to the batch file.

    EquipmentMethodParameters
    Brookfield RVT ViscometerASTM D2196Viscosity (cP), hydration rate
    Fann 35 ViscometerAPI 13ADrilling-grade performance
    IR Moisture AnalyzerAACC 44-19Moisture %
    Tyler Sieve SetIS 7553Particle size distribution
    Digital pH MeterIS 7553pH (1% solution)
    Muffle FurnaceIS 7553Ash content
    Kjeldahl ApparatusAOAC 954.01Protein / nitrogen
    Autoclave + IncubatorIS 5402, USPMicrobial counts
    GC-MS (outsourced for confirmation)EU 2026/196ETO residue

    Certificate of Analysis (CoA)

    Every shipment leaves Kalol with a batch-specific Certificate of Analysis. The CoA is generated from the actual laboratory record for that lot — not a generic specification sheet reprinted with a new date — so an incoming QC team can compare measured values directly against the agreed specification and release the material without re-testing.

    Batch number and lot traceability reference
    Date of manufacture and shelf-life dating
    Every tested parameter with the result shown against its specification
    QC officer sign-off and release authorisation

    Retained samples from each batch are held in our sample library so any query raised months after delivery can be investigated against the original material. Sample CoAs for any grade are available on request — useful when a purchasing or regulatory team needs to review the document format before placing a first order.

    Quality Lab FAQs

    Do you test every batch?

    Yes. 100% of batches undergo full testing before release. No batch ships without a signed Certificate of Analysis from our QC team.

    What viscosity measurement method do you use?

    We use a Brookfield RVT viscometer at defined spindle speeds for food and cosmetic grades, and a Fann 35 viscometer for drilling-grade testing per API 13A specifications.

    Can you test to custom specifications?

    Yes. If your formulation requires testing at specific concentrations, temperatures, or for additional parameters beyond our standard panel, we accommodate custom testing protocols.

    How do you test for ETO residue?

    Initial screening is done in-house. Confirmation testing is performed via GC-MS at an accredited third-party laboratory, with results to the EU limit of quantification of 0.1 mg/kg per Regulation 2026/196.

    Is your lab ISO 17025 accredited?

    Our laboratory follows ISO 17025-aligned methods and procedures. Formal accreditation is in progress. For parameters requiring accredited results (e.g., ETO, heavy metals), we use NABL-accredited partner labs.

    What is the shelf life of your guar gum?

    Properly stored (cool, dry conditions below 25°C, away from moisture), HICOL guar gum has a shelf life of 24 months from the date of manufacture.

    Related Pages

    ISO, FSSAI, Halal, Kosher and FDA compliance details

    Inside our 12,000 MT/year plant in Gujarat, India

    Food, pharma, industrial and specialty Guar Gum grades

    Discuss custom testing protocols with our QC chemists

    Request a Sample CoA

    Tell us which grade you are evaluating and we will send a representative Certificate of Analysis along with the full specification sheet.

    Request a Sample CoA
    Chat with us